Industrial IoT for Sheet Metal Stamping Presses
Crimson connects existing stamping presses without replacing their controls. Run status, production count and the interlock line are read as wired I/O into a PLC on the machine. Optional sensors for energy, oil pressure, air flow and temperature feed the same PLC over RS-485 and 4-20 mA. A Modbus gateway buffers timestamped records and pushes them onward over the network, so a connection outage delays delivery rather than losing production data.
- Signals read
- Run status, production count, interlock
- Machine interface
- Wired I/O and existing relays
- Sensor buses
- RS-485 and 4-20 mA
- Transport
- Ethernet, Modbus, MQTT, GSM
- Gateway buffer
- 17,000 timestamped records
- Commissioning
- Three days per press
In the product
The deployed signal path. The crimson leg is the command that returns to the press.
What it does
- Derived topic addresses
- Each asset's address is built from its place in the plant model, so nothing is typed twice.
- Buffered delivery
- The gateway holds records with a real time clock, so a network drop delays rather than loses data.
- Optional condition sensors
- Energy, oil pressure, air flow and chiller temperature on the same PLC.
- Command path back to the press
- The interlock is a wired line, so the platform can stop a press and not only report one.
How it works
Read the machine
Crank encoder and existing relays into the PLC as wired I/O.
Add sensors if wanted
Energy meter over RS-485, pressure and flow over 4-20 mA.
Push to the platform
Ethernet to the Modbus gateway, then onward over the network to Crimson.
Who this is for
- Presses from several makers and several decades on one floor.
- A plant with no network run to the machines, using GSM instead.
- An operation that wants condition data before committing to a maintenance model.
Questions
- Do we need to change the press controls?
- No. The signals are read from the encoder and the relays already present.
- Which protocols are supported?
- Wired I/O, RS-485, 4-20 mA, Ethernet, Modbus, MQTT and GSM. OPC-UA is not supported.
- What happens if the network drops?
- The gateway keeps buffering with a real time clock and delivers when the link returns.
- Can older presses be connected?
- Yes. The interface is the encoder and relay level, which is why press age matters less than you would expect.